Technical data
- Range.
- Threaded ends from DN32 to DN80.
- Flanged ends from DN40 to DN300.
- Threaded type: BSP acc to ISO 228-1.
- Flanged type: EN 1092-2 PN16 and AS4087 (AS2129 Talbe E).
- Maximum working pressure 16bars.
- Operating temperaturas 10ºC ~ 80ºC.
- Seating acc to category A estándar ISO 5208.
- Minimum backpressure for tightness: 0.3bar to 0.5bar.
- Face to Face dimensions for flanged type according to EN-558-1 serie 48 (DIN3202 F6).
Aplications
Pumping stations for clean, sewage wáter and loaded or viscous fluids.
Hydraulic Test
- Seat: 1.1x normal pressure.
- Body: 1.5x normal pressure